HyperGate LITE is an embedded gateway device that allows the online management of gates over Bluetooth protocol. The HyperGate device allows you to remotely update the lock memory (white-list), authorizing or deactivating new users, cards, and smartphones. In addition, HyperGate LITE allows remote opening of the door, as well as reading the lock history via browser or smartphone device remotely.
| Category | Aspect | Recommendation / Warning |
| Distance & Signal Range | Distance to Smart Lock | Max 10 m with direct line of sight; optimal performance between 4–7 m. |
| Line of Sight | Line of sight is required between the gateway and the smart lock antenna for best performance. | |
| Smart Lock BLE signal power | It is suggested that you enter the smart locks setting and set both the BLE signal power to the maximum value. Please consider that this impacts the battery duration. | |
| Smart Lock LBE advertising frequency | If the environment results to be very noisy in terms of radio signals, consider setting the BLE advertising frequency of the smart lock to the maximum value. Please consider that this has an impact on the battery duration. | |
| Recommended Gateway Load | Number of connected locks | 2–4 doors per gateway on average. 10–15 smart locker locks per gateway (depending on layout) |
| Placement | Mounting Height | 2–3 meters above floor level to minimize interference and improve signal propagation. |
| Gateway Orientation | Point toward the smart lock; avoid placing it inside metal boxes or behind solid obstacles. | |
| Metal Doors or Coatings | If installed inside the door or room, verify the door is not made of metal or coated with metallic paints—these significantly degrade the BLE signal. | |
| Leaded or Coated Glass | Glass doors with metallic coatings or leaded glass (e.g., acoustic or radiation shielding) can severely weaken signal—test performance before confirming the setup. | |
| Interference | Magnetic Fields | Avoid installation near electric motors, transformers, door engines, or large power adapters. |
| Other 2.4 GHz Sources | Maintain a minimum 2-meter distance from Wi-Fi routers, microwave ovens, or Bluetooth emitters. | |
| Connectivity | Preferred Connectivity | Use Power over Ethernet (PoE) for stable power and data; Wi-Fi only if stable and interference-free. |
| Environment | Humidity & Moisture | In humid areas (bathrooms, kitchens, semi-outdoors), protect the device from condensation and corrosion; humidity may reduce performance. |
| Nearby Surfaces | Avoid proximity to metal surfaces that reflect or absorb signals; ensurea clear space around the antenna. | |
| Maintenance | Firmware Updates | Keep the gateway firmware updated to benefit from the latest security patches and performance enhancements. |
| Signal Testing | After installation, test the actual smart lock response to confirm reliability. |
Warnings
- Read this manual prior to use the device in order to ensure a safe and proper use. Preserve this manual as future reference.
- The installation and maintenance of the device must be carried out by qualified technical staff, adequately trained by Sofia part of ISEO.
- The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be passed on by the installer to the user.
- The product must be destined only for the use for which it is expressly designed. Any other use is considered improper and dangerous.
- The electrical connection must be made according to the constructor’s instructions and respecting the regulations in force.
- Disconnect the power supply before carrying out any technical service that involves opening or accessing the internal parts of the product. For all repairs, exclusively contact a technical assistance center authorized by the constructor
- Dispose of the product separately from household waste, in accordance with local laws and regulations.
- Operating and storage temperature: -20°C/+50°C with Relative Humidity Max. 95% without condensing